New

Flir IR6

Wide Dynamic Range Infrared Machine Vision Camera

The Flir IR6 brings high-resolution thermal measurement to machine vision and industrial automation, combining 640 × 480 imaging at 60 Hz with wide dynamic range and a compact, rugged design. By capturing temperature data across a broad measurement range without manual subrange switching, the IR6 helps manufacturers monitor fast-moving processes, identify thermal variations, and make more informed automated inspection decisions.

Designed for seamless integration, the IR6 supports GigE Vision, GenICam, and Power over Ethernet (PoE), making it easier to incorporate thermal imaging into existing machine vision systems. From quality assurance and process control to early fire detection and critical asset monitoring, the IR6 delivers detailed thermal data to help improve efficiency, consistency, and operational reliability.

Accurately measure temperatures from -20°C to 1500°C without manual subrange switching, allowing the IR6 to continuously capture changing thermal conditions. With 640 × 480 resolution at 60 Hz full frame, the Flir IR6 helps monitor rapidly changing temperatures and fast-moving processes, supporting consistent measurements and more confident automated inspection.
Integrate thermal imaging into existing machine vision and automation systems with GigE Vision and GenICam compatibility. Support for Atlas and Spinnaker SDKs, Gigabit Ethernet, and Power over Ethernet (PoE) helps streamline development, reduce cabling complexity, and accelerate deployment for OEM and industrial applications.
Bring advanced thermal measurement into space-constrained systems with an ultra-compact design measuring just 29 × 37 × 56 mm and weighing approximately 65 g (2.23 oz) without the lens. Engineered for flexible integration, the Flir IR6 fits into tight enclosures, automated equipment, and OEM machine vision systems without compromising imaging performance.

One Range. Different Temperatures.

Industrial processes can involve significant temperature differences, sometimes within the same field of view. IR6 captures hot and cold areas in the same frame across a -20°C to 1500°C (-4°F to 2732).

Request a demo

IR6 Applications

Thermal Process and Quality Inspection

Detect thermal defects in-cycle, including seals, welds, adhesives, and batteries. At 60 Hz, IR6 captures thermal changes in moving processes for in-cycle inspection.

Process and quality inspection

OEM Thermal Machine Vision Integration

Add thermal measurement to machines, robotics, and automated inspection systems. Its compact design and GigE Vision and GenICam connectivity make IR6 suited to OEM designs where space and integration matter.

OEM machine integration

Thermal Imaging Before There is Smoke

Monitor heat to help identify abnormal conditions before visible smoke or flame develops. Continuously measure thermal conditions across battery energy storage sites, recycling facilities, warehouses, flares, and other high-risk environments.

Early fire detection

Thermal Monitoring for Critical Assets

Thermal changes can indicate developing equipment faults before failure occurs. Use continuous, non-contact thermal monitoring to track electrical cabinets, motors, transformers, bearings, and other critical assets.

Critical asset monitoring

Flir IR6 Frequently Asked Questions

The Flir IR6 supports automated thermal inspection, industrial process monitoring, quality control, early fire detection, and equipment condition monitoring. It helps industrial systems identify temperature variations and abnormal thermal conditions.

The Flir IR6 provides calibrated temperature measurement from -20°C to 1500°C (-4°F to 2732°F ). Its wide dynamic range reduces the need for manual subrange switching.

Yes. The Flir IR6 supports GigE Vision and GenICam, along with Gigabit Ethernet and Power over Ethernet connectivity, enabling integration into compatible machine vision, robotics, and industrial automation systems.

The Flir IR6 captures full-frame thermal images at 60 Hz with 640 × 480 resolution, supporting temperature monitoring and inspection of moving products and industrial processes.

The Flir IR6 measures 29 × 37 × 56 mm (1.14 × 1.45 × 2.20) and weighs approximately 65 grams (2.23 oz) without a lens, making it suitable for space-constrained OEM and industrial automation installations.

Specifications

Highlighted
Ethernet Interface Wired
Mounting Lens Mount: VGA - M25
f-number 1.2
Image Frequency 60 Hz
Thermal Sensitivity/NETD ≥40 mK; f/1.0, 25°C (77°F) object, 22°C (71.6°F), ambient, spatial, and temporal filtering applied
Accuracy ±5°C or ±5% of reading, whichever is greater**

**Field accuracy depends on system integration and scene conditions. Very small or cold targets next to much hotter backgrounds may read less accurately.
Communication & Data Storage
Connector Type RJ45 Ethernet Connector
Ethernet Purpose: Control, Image, Power
Ethernet Communication GigE Vision / GenICam
Ethernet Interface Wired
Ethernet Power Power over Ethernet (PoE)
Ethernet Protocols GigE Vision
Ethernet Standard IEEE 802.3
Ethernet Type Gigabit Ethernet
Imaging & Optical
Available Lenses VGA Focal Length:
7 mm
8.5 mm
14 mm
19 mm
25 mm
Detector Pitch 17 µm
f-number 1.2
Focus Manual
Image Frequency 60 Hz
Infrared Resolution 640 × 480 pixels
Spectral Range 7.3–14 μm (LWIR)
Thermal Sensitivity/NETD ≥40 mK; f/1.0, 25°C (77°F) object, 22°C (71.6°F), ambient, spatial, and temporal filtering applied
Measurement & Analysis
Accuracy ±5°C or ±5% of reading, whichever is greater**

**Field accuracy depends on system integration and scene conditions. Very small or cold targets next to much hotter backgrounds may read less accurately.
Calibration -20°C to 1500°C (-4°F to 2732°F)*

*600°C to 1500°C (-1048°F to 2732°F) with burn-in management
General
Size [L x W x H ] w/o Lens 29 mm × 37 mm × 56 mm
Weight [without lens] 65 g (2.47 oz)
Environmental & Certifications
Humidity (Operating and Storage) Maximum 80% relative humidity, non-condensating
Mounting Lens Mount: VGA - M25
Operating Temperature Range -20°C to 60°C (-4 to 140°F)
*To avoid possible damage during storage, ensure that the sensor is not exposed to air. Use a lens cap or lens to cover the sensor
Tripod Mounting 1/4"-20
Power
Power Consumption Typical:

12 V: 2.8 W
24 V: 2.8 W
PoE (48 V) 3.5 W

Maximum:

12 V: 4.4 W
24 V: 4.4 W
PoE (48 V) 4.8 W

Resources & Support

Datasheet

FLIR IR6 Datasheet

Export Restrictions

The information contained in this page pertains to products that may be subject to the International Traffic in Arms Regulations (ITAR) (22 C.F.R. Sections 120-130) or the Export Administration Regulations (EAR) (15 C.F.R. Sections 730-774) depending upon specifications for the final product; jurisdiction and classification will be provided upon request.

Cart

Added to cart